Australian window compliance involves two standards that builders, developers, and importers frequently conflate: AS2047 and AS4420. Understanding the distinction — and the fact that “AS2047 Certified” is technically a misnomer — is essential for any company supplying windows to the Australian market. This guide explains what each standard covers, how the declaration of conformity system works, how compliance is verified, and how BAL ratings intersect with window specification for bushfire-prone areas.
1 AS2047 vs AS4420: What Each Standard Covers
AS2047 vs AS4420 is not a choice between two competing standards — they do different jobs. AS2047 sets the performance ratings a window must achieve: wind load, water penetration, air infiltration and structural adequacy. AS4420 sets the laboratory test methods used to prove those ratings. “AS2047 Certified” is therefore not a thing; compliance is evidenced by a declaration of conformity backed by NATA-accredited test reports.
| Aspect | AS 2047 | AS/NZS 4420 |
|---|---|---|
| Full title | Windows and external glazed doors in buildings (AS 2047:2014) | Windows, external glazed, timber and composite doors — Methods of test (AS/NZS 4420.1:2016) |
| Role | Sets the performance ratings a window must achieve | Sets the laboratory test methods used to prove those ratings |
| Scope | Wind load (serviceability and ultimate), water penetration, air infiltration, structural adequacy; selection and installation provisions | Test sequence, sampling, deflection, operating force, air infiltration, water penetration, ultimate strength |
| Applies to | Manufacturers, importers, specifiers and certifiers | NATA-accredited laboratories and test houses |
| Compliance evidence | Declaration of Conformity issued under the supplying brand | The NATA-accredited test report itself (AS 4420.2–.6) |
The AS2047 vs AS4420 pairing is read together, not chosen between. AS2047 sets the rating; AS4420 is the rulebook the laboratory follows to produce the evidence. Installation is addressed in AS2047’s own selection and installation provisions and in the National Construction Code, not in AS4420 — a window that passed its AS4420 tests can still fail in the field if it is fixed or sealed contrary to the tested configuration.
2 Why ‘AS2047 Certified’ Doesn’t Exist: The Declaration System
One of the most common misconceptions in the Australian window market and the reason the AS2047 vs AS4420 distinction matters commercially is the phrase “AS2047 Certified.”No government body or standards organization issues an “AS2047 certificate.” Instead, compliance is demonstrated through a Declaration of Conformity — a formal statement by the manufacturer or supplier that their product meets AS2047 performance requirements, backed by test data from a NATA-accredited laboratory.
Key points about the declaration system:
- No certificate exists: AS2047 is a performance standard, not a certification scheme. There is no “AS2047 certificate” issued by Standards Australia or any regulatory body.
- Declaration of Conformity: The manufacturer issues a formal declaration stating the product meets AS2047 requirements, supported by NATA lab test reports.
- Evidence required: Test reports from a NATA-accredited laboratory must demonstrate compliance with each relevant performance requirement (wind, water, air, structural).
- Responsibility: The entity placing the product on the Australian market (importer, distributor, or manufacturer) holds responsibility for the declaration.
This system means that importers and distributors cannot simply reference a factory’s test data under a different brand name. The declaration must be issued under the brand name of the entity supplying the Australian market, with test specimens matching the exact product configuration being sold.This is where the AS2047 vs AS4420 distinction becomes commercial rather than academic — the paperwork follows the brand that places the product on the market, not the factory that produced it.
For importers working with overseas manufacturers, StarveilBuild provides full test specimen preparation and NATA-compatible test documentation, with the declaration of conformity issued under the buyer’s own brand. The certificate belongs to the buyer, not the factory.

3 Conformity Assessment: How Compliance Is Verified
Conformity assessment is where the AS2047 vs AS4420 split becomes practical: window specimens are tested at a NATA-accredited laboratory and the results documented in a formal test report. The assessment covers five primary performance requirements, each tested to specific methods defined in the AS 4420 series of standards.
| Requirement | Test Standard | What It Measures | Pass Criteria |
|---|---|---|---|
| Structural adequacy | AS 4420.2 | Deflection under design wind load | Deflection ≤ L/150 (housing), L/180 (residential), L/250 (commercial) |
| Operating force | AS 4420.3 | Force required to open and close the sash | ≤ 110 N to initiate, ≤ 90 N to sustain (horizontal sliding sash) |
| Air infiltration | AS 4420.4 | Air leakage rate at ±75 Pa | ≤ 1.0 L/s·m² (air-conditioned); ≤ 5.0 L/s·m² (non-air-conditioned) |
| Water penetration | AS 4420.5 | Water ingress under pressure differential plus spray | No penetration at rated pressure (N1/N2 150 Pa → N6/C4 450 Pa), held 15 min |
| Ultimate strength | AS 4420.6 | Resistance to ultimate wind load | No failure at 150% of serviceability pressure, held 1 min |
The conformity assessment process typically follows these steps:
- Determine the wind classification for the project location (N1 to N4, C1 to C4, or D as per AS4055).Wind classifications and the deemed-to-satisfy pathway are set out in the National Construction Code 2022
- Select window products rated for the required wind class
- Submit test specimens to a NATA-accredited laboratory
- Receive test reports documenting performance for each requirement
- Issue a Declaration of Conformity referencing the test reports
- Provide documentation to builders, certifiers, and building surveyors
NATA accreditation is critical — test reports from non-NATA laboratories are not accepted for AS2047 compliance evidence in Australia. StarveilBuild coordinates NATA lab testing for Australian buyers, providing test specimens manufactured to the exact production configuration.A certifier reading an AS2047 vs AS4420 evidence pack looks for the NATA accreditation mark before anything else; without it, the test data has no standing.
4 BAL Ratings & AS3959: Bushfire Zone Windows
In addition to AS2047, windows installed in bushfire-prone areas must comply with AS3959, the Australian Standard for construction in bushfire-prone areas. AS3959 defines Bushfire Attack Level (BAL) ratings that determine construction requirements based on fire risk. These ratings affect glass thickness, frame material, and screening requirements for windows and doors.
| BAL Rating | Risk Level | Glass Requirement | Frame Requirement | Screening |
|---|---|---|---|---|
| BAL-Low | Low | 4mm minimum | Standard | None |
| BAL-12.5 | Low | 4mm minimum | Standard | Mesh required |
| BAL-19 | Moderate | 5mm minimum | Standard | Mesh required |
| BAL-29 | High | 5mm toughened | Aluminum acceptable | Mesh required |
| BAL-40 | Very high | 6mm toughened or laminated | Non-combustible | Mesh required |
| BAL-FZ | Flame zone | 6mm toughened + screened | Non-combustible, protected | Mesh + special design |
Key considerations for BAL-rated windows:
- Glass thickness: Higher BAL ratings require thicker, tougher glass to resist radiant heat and ember attack
- Frame material: Aluminum is non-combustible and acceptable for all BAL ratings including BAL-FZ
- Fly screens: BAL-rated stainless steel mesh screens (aperture less than 1.8mm) are required for operable windows in BAL-12.5 and above
- Seals: Intumescent or fire-resistant seals may be required for BAL-40 and BAL-FZ
StarveilBuild manufactures aluminum window and door systems suitable for BAL-29 and BAL-40 applications, with test specimens available for AS3959 compliance verification under the buyer’s brand.BAL construction requirements are administered by the Australian Building Codes Board.
5 Importer Compliance Checklist: 10 Steps to Market
For importers and distributors bringing aluminum windows into the Australian market, the following checklist runs in the order an AS2047 vs AS4420 evidence pack is actually assembled from factory selection through market entry. Following this sequence helps avoid the most common compliance pitfalls that delay product launches.
- Verify manufacturer capability: Confirm the factory produces to AS2047 performance requirements and can provide test specimens matching your product configuration
- Determine wind classification: Identify target markets (N1 to N4 for non-cyclonic, C1 to C4 for cyclonic regions) based on your distribution area
- Select product configurations: Choose window and door types, sizes, and glass packages for your product range
- Prepare test specimens: Factory manufactures specimens matching the exact production configuration intended for sale
- Submit to NATA laboratory: Engage a NATA accredited lab for AS4420.2 through .6 testing
- Receive test reports: NATA reports must cover deflection, operating force, air infiltration, water penetration and ultimate strength (AS 4420.2 to .6), and every result must be checked against the wind class you selected before a declaration is issued
- Issue Declaration of Conformity: Prepare formal declaration under your brand name, referencing the test reports
- Prepare installation documentation: Create fixing and sealing guides that match the tested configuration (installation is covered by AS2047 and the NCC, not AS4420)
- Register with WERS (optional): Submit energy rating data to the Window Energy Rating Scheme for marketing advantage
- Maintain records: Retain test reports, declarations, and production records for a minimum of 7 years
Common compliance pitfalls for importers to avoid:
- Using factory test data under a different brand name (non-compliant — declaration must be under your brand)
- Testing only one size and assuming all sizes pass (each configuration needs evidence)
- Ignoring cyclonic region requirements (C-rated products need separate testing)
- Overlooking BAL requirements for bushfire zone markets
- Failing to update declarations when product specifications change
StarveilBuild supports Australian importers through every step of this AS2047 vs AS4420 checklist, from specimen manufacturing through NATA lab coordination, with all declarations and certificates issued under the buyer’s brand identity.
Frequently Asked Questions
Q: Can a manufacturer be "AS2047 Certified"?
A: No. AS2047 is a performance standard, not a certification scheme. No body issues an "AS2047 certificate." Compliance is demonstrated through a Declaration of Conformity issued by the manufacturer or importer, backed by NATA-accredited laboratory test reports. The declaration must be under the brand name of the entity supplying the Australian market.
Q: Do I need separate testing for cyclonic and non-cyclonic regions?
A: Yes. Windows rated for non-cyclonic regions (N1 to N4) and cyclonic regions (C1 to C4) have different test requirements under AS2047. Products intended for cyclonic areas undergo additional cyclic loading tests. Separate test specimens and reports are needed for each wind class.
Q: Can I use my overseas factory's test reports for Australian compliance?
A: Only if the test reports are from a NATA-accredited laboratory (or a lab with MRA recognition) and the Declaration of Conformity is issued under your Australian brand name. Factory test data from non-NATA labs cannot be used as compliance evidence. StarveilBuild provides test specimens and coordinates NATA testing with certificates issued under the buyer's brand.
Q:AS2047 vs AS4420 — what is the difference?
A:AS2047 sets the performance ratings a window must achieve: wind load, water penetration, air infiltration and structural adequacy. AS4420 sets the test methods a NATA-accredited laboratory uses to prove those ratings. A product is rated to AS2047 on the basis of its AS4420 test reports — neither standard replaces the other.
Download Free AS2047 vs AS4420 Comparison Sheet Side-by-side standard comparison, test methods, and importer compliance checklist for Australian window market entry. Download Resource →