Munich Passive House Villa
Uw0.78 Tested | 86 Units

Triple Glazing | PHI-Ready | Low Air Leakage
Minimal thermal break frames for European passive standards. Full notified body CE documentation.
Our passive house aluminum systems are engineered to EN 14351-1, Passive House Institute Uw0.8, and CE marking performance thresholds, with ITT/FPC documentation for notified-body review.
Systems are engineered to European EN 14351-1 and Passive House performance targets. We provide ITT specimens, thermal calculations, installation details, and technical documentation for your notified-body submission. Final CE documentation is issued under the buyer’s company name.
View certification process →| Parameter | Our Production Target | European reference | Passive House / CE | Status |
|---|---|---|---|---|
| Thermal Transmittance Uw | Uw≤0.8 W/(m²K) | Uw≤1.0 | PHI target | In-house validated |
| Air Permeability | Class 4 | Required | Required | In-house validated |
| Water Tightness | Class E900 | EN 12208 | E900 | In-house validated |
| Wind Load | Class C5 | EN 12210 | C5 | In-house validated |
From thermal review to CE documentation, with a structured workflow for European project approval.
Review project climate zone, opening sizes, target standard, drawings, and local approval route.
Week 1Build full-size specimens to the nominated configuration, glazing, hardware, and performance target.
Week 2–4Coordinate the applicable accredited laboratory tests and record the performance data required for submission.
Week 5–8Prepare calculations, drawings, installation details, declarations, and supporting test documentation.
Week 9–10Support the nominated local authority, notified body, or certification route through final documentation.
Week 11–12Thermal targets, installation details, and CE documentation are confirmed against the project specification and nominated market.

Uw0.78 Tested | 86 Units

Uw0.80 | 156 Units

Uw0.75 | 412 Units

Thermally broken sliding door engineered to Uw≤0.8 W/(m²K) for passive house projects, with complete EN 14351-1 technical documentation for notified-body submission.
Discuss this system →
PA66 thermal-break tilt-turn window engineered to Uw≤0.8 thermal targets. ITT specimens are available for EN 14351-1 protocol review.
Discuss this system →
Triple-glazed fixed window engineered to Uw≤0.8 passive house targets, with ITT specimens available for notified-body certification.
Discuss this system →
Heavy-duty entrance door engineered to European passive-house thermal thresholds with CE documentation for local authority approval.
Discuss this system →Send your drawings, performance targets, and project location. Our engineers will respond within 24 hours.
Start the technical review →Yes. We review the profile, glazing, hardware, dimensions, and installation details before preparing the applicable technical documentation.
The range is engineered around Uw≤0.8 W/(m²K), subject to the selected configuration, dimensions, glass, spacer, and installation conditions.
Project-specific specimens and supporting calculations can be prepared for the nominated notified-body or laboratory route.
Documentation and declarations are coordinated through the applicable legal manufacturer and project certification route.