Discuss Your Project

Engineering Test Data & Reports

Third-party tested performance data organized by regional standard.

Test document update: New AS2047 water penetration data and NFRC U-factor results are available for project review. View reports

Aluminum window systems are engineered to NFRC, CE, AS2047 and CSA performance thresholds. In-house QC data and third-party specimen documentation are available to support your local certification submission.

Test Data by Region

Select the report package that matches your target market. Datasheets are supplied after project and product scope confirmation.

6 reports
Selected: 0
North America NFRC 100/200 · CSA A440S1

North America NFRC Performance Test Data

Energy performance and structural compliance for US and Canadian building codes.

ProductU-factorSHGCVTAirWaterStructural
Casement 0.29 BTU/h·ft²·°F 0.27 0.52 0.04 cfm/ft² 7.5 psf DP50
Awning 0.31 BTU/h·ft²·°F 0.24 0.48 0.05 cfm/ft² 6.0 psf DP45
Fixed 0.25 BTU/h·ft²·°F 0.30 0.58 0.01 cfm/ft² 9.0 psf DP60
Sliding 0.33 BTU/h·ft²·°F 0.29 0.55 0.08 cfm/ft² 5.5 psf DP40
Request Engineering Datasheet → Certification partnership support
Europe CE EN 14351-1 · EN 12150

Europe CE EN Test Documents

CE performance data for windows and doors, including thermal, weather and acoustic values.

ProductUw (W/m²K)AirWaterWindAcoustic Rw
Tilt-Turn 0.8 Class 4 Class 9A Class B5 38 dB
Casement 1.1 Class 4 Class 8A Class B4 35 dB
Fixed 0.7 Class 4 Class 9A Class B5 40 dB
Lift-Slide 1.3 Class 3 Class 7A Class B3 33 dB
Request Engineering Datasheet → Certification partnership support
Australia AS2047 · AS1288

Australia AS2047 Performance Test Data

AS2047 performance data for Australian wind, water and glazing conditions.

ProductWater (Pa)Wind (Pa)AirDeflection
Awning 300 2000 0.89 L/s·m² Span/150
Casement 450 2400 0.72 L/s·m² Span/150
Sliding 200 1600 1.45 L/s·m² Span/180
Double Hung 150 1400 1.80 L/s·m² Span/180
Request Engineering Datasheet → Certification partnership support
Canada CSA A440S1 · ENERGY STAR

Canada CSA A440S1 Test Data

Canadian performance grades and ENERGY STAR thermal targets for cold-climate projects.

ProductU-factorERAirWaterZone
Casement 1.4 W/m²K 25 A3 B7 A, B, C
Tilt-Turn 1.2 W/m²K 29 A3 B7 A, B, C, D
Fixed 1.0 W/m²K 34 A3 B7 A, B, C, D
Sliding 1.7 W/m²K 19 A2 B4 A, B
Request Engineering Datasheet → Certification partnership support
Middle East GSO SASO · Salt Spray

Middle East High Temperature Test Data

High-temperature, UV, thermal cycling and corrosion data for Gulf and desert climates.

ProductMax TempSalt SprayUVThermal Cycling
Sliding Door 80°C 3000 hrs Class A −20°C to +80°C
Curtain Wall 85°C 4000 hrs Class A+ −30°C to +85°C
Fixed Window 80°C 3000 hrs Class A −20°C to +80°C
Request Engineering Datasheet → Certification partnership support
Global ISO 9001:2015 QMS

ISO 9001:2015 Quality Management System

Documented factory quality management procedures from incoming profile inspection through final pre-shipment QC.

Control areaEvidenceReview
Incoming materials Profile, glass and hardware inspection Documented
In-process production Work instructions per station Traceable
Final inspection Four-stage QC and serial records Recorded
Surveillance Annual third-party audit Current through 2027
Request Engineering Datasheet → Certification partnership support

ISO 9001:2015 Certified Factory

Certificate No. SB-ISO9001-2024

Quality Management System

Every production line follows documented procedures from raw profile inspection through final pre-shipment QC, with traceable records for every unit and annual third-party surveillance audits.

ISO
9001

ISO 9001 is factory quality management certification, not a regional window performance certificate. NFRC, CE, AS2047, CSA and NOA routes require product-specific specimens and engineering documentation.

Customers Building Their Own Certification

Florida, USA

Miami-Dade NOA

10 weeks

Test specimens and engineering documents aligned to the customer’s production configuration.

DP50+ casement and fixed windows

Queensland, Australia

AS2047 Compliance

8 weeks

Test specimens and engineering documents aligned to the customer’s production configuration.

Awning and casement windows

Munich, Germany

CE EN 14351-1

12 weeks

Test specimens and engineering documents aligned to the customer’s production configuration.

Tilt-turn and fixed windows

Test Data & Certification Questions

Do you hold Miami-Dade NOA or Florida Product Approval certificates?

No. StarveilBuild is a certification-ready manufacturer. We provide DP50+ test specimens and engineering documentation for your local certification submission; the certificate is issued under your brand.

What test data do you provide with each order?

Orders can include in-house QC data, third-party specimen reports for the target market, drawings, material specifications and glass performance data.

How much does certification cost, and who pays?

Fees vary by standard and laboratory. The brand owner pays the laboratory directly while we provide the agreed specimens and engineering documentation.

Who owns the certification?

The customer owns certificates issued under its company name and brand. StarveilBuild is listed as manufacturer of record where applicable.

How long does certification take?

A typical certification route takes approximately 8 to 12 weeks from specimen shipment to certificate issuance, depending on the standard and authority.

Can specimens match our exact product specification?

Yes. We can produce specimens with the same profile, glass, hardware and finish as the production configuration, with traceability records.